Sub-Zero error code · 60 2 60
Sub-Zero Code 60 2 60: No Freezer Compressor Load Detected
Sub-Zero code 60 2 60 means no electrical load was detected at the freezer compressor. Check compressor electricals, start components, and wiring; the freezer.
Sub-Zero code 60 2 60 means the control board commanded the freezer compressor on but detected no electrical load drawing current. Per Sub-Zero, check the compressor electricals and wiring; the cause is usually an open start component, broken connection, or a failed compressor.
What 60 2 60 means
The board monitors current draw to confirm the freezer compressor actually energizes. With code 60 2 60, the board called for cooling but sensed essentially zero load, meaning the compressor is not drawing power. The freezer will not pull down to temperature while this condition is present, and the SERVICE light turns on.
Severity:Service needed · Service light:ON
Common causes
- Failed compressor start relay or overload protector
- Open or broken wiring/terminal in the compressor circuit
- Failed start device or start capacitor
- Compressor with open motor windings
- Connector unseated at the control board or compressor
Why 60 2 60 happens
An open circuit anywhere in the compressor path produces no load: a failed start relay or overload, an open start capacitor or start device, a broken or corroded wire or terminal, or a compressor with open windings. Age, heat in the compressor compartment, and vibration loosening terminals are common contributors.
What you'll typically see
- Freezer not cooling and contents thawing
- Compressor silent, no hum or start attempt
- SERVICE light illuminated
- Possible clicking from the overload protector trying to start
- Code 60 2 60 stored in diagnostics
Parts involved in 60 2 60
- Compressor start relay and overload — Most common when the compressor itself tests good but will not draw current
- Compressor wiring harness/terminals — Repair or replace where an open or corroded connection is found
- Freezer compressor — Replace only if windings test open or shorted and supply is confirmed good
What you can check yourself
- Power the unit off for two to three minutes, then restore power and listen for the compressor to attempt a start
- Verify the household breaker is on and the unit is fully powered
- Note whether the freezer is the only section warming
- Record the code for the technician
When to book a pro
Confirming an open compressor load requires metering start components and motor windings on live high-voltage circuits, which is unsafe and impractical for an owner.
Have this code?
Send us the code and your model — flat $89 diagnostic, 365-day warranty.
Book a technicianHow to enter service mode →All Sub-Zero error codesAll brands
Frequently asked
60 2 60 FAQ
What does code 60 2 60 mean on my Sub-Zero?
Code 60 2 60 means the control board commanded the freezer compressor on but detected essentially zero electrical load, so the compressor is not drawing power. The board monitors current draw to confirm the compressor energizes, and when it sees none it lights the SERVICE light and logs 60 2 60. The usual culprits are an open start relay or overload, a broken connection, a failed start device, or a compressor with open windings.
Is 60 2 60 a repair I can do myself?
No. You can power the unit off for two to three minutes and listen for the compressor to attempt a start, verify the household breaker is on, and note whether only the freezer is warming. Confirming an open compressor load, though, means metering start components and motor windings on live high-voltage circuits, which is unsafe and impractical for an owner.
How do I clear the 60 2 60 service code?
Try powering the unit off for two to three minutes, then restore power and listen for a start attempt. If the compressor still draws no load, 60 2 60 and the SERVICE light return because the open circuit is still there. The code clears for good only after the failed start relay, overload, wiring, or compressor is repaired and normal current draw returns.
How urgent is a 60 2 60 fault?
Urgent for your frozen food. With no compressor load the freezer will not pull down to temperature and contents will thaw, and you may hear the overload protector clicking as it repeatedly tries to start. Move frozen items if possible and schedule service promptly rather than letting the section warm.
Which parts are involved in 60 2 60 and what does it cost?
Most often it is the compressor start relay and overload when the compressor itself tests good, sometimes a corroded or open wiring terminal, and the freezer compressor only if its windings test open or shorted with supply confirmed good. We charge a flat $89 diagnostic to isolate the fault and back the repair with a 365-day warranty. Call (650) 668-1554.
How is 60 2 60 different from the freezer communication codes 60 2 02 and 60 2 38?
60 2 60 is a no-load fault: the board sees no current at the freezer compressor, an electrical open in the start circuit or windings. The 60 2 02 and 60 2 38 codes are communication faults where the board loses its data link to the variable-speed inverter drive. So 60 2 60 is diagnosed by metering the compressor electricals, not by checking the inverter data link.
Subzero Repair · Open 24/7 · 365-day warranty
Need a high-end appliance repaired?
Call for urgent cooling or cooking failures, or book online for a service window across the Bay Area.