Sub-Zero error code · 20 2 06
Sub-Zero Code 20 2 06: Mis-Wired Defrost Bi-Metal
Sub-Zero Code 20 2 06 means a mis-wired or misplaced defrost bi-metal caused high temps during defrost. Fix the wiring and bi-metal mounting.
Sub-Zero Code 20 2 06 means the defrost bi-metal is mis-wired or improperly mounted, so the control saw abnormally high temperatures during defrost and an inappropriate response from the bi-metal. The fix is to correct the bi-metal wiring and remount it correctly against the evaporator, replacing it if its mounting or sensing surface is damaged.
What 20 2 06 means
This code reports that the defrost termination bi-metal did not respond the way the control expected during a defrost cycle, while evaporator temperatures climbed too high. The control interprets this combination as a wiring or mounting fault rather than a normal end-of-defrost signal. In short, the bi-metal that should sense and limit defrost heat is not connected or positioned to do its job.
Severity:Service recommended · Service light:ON
Frequently asked
20 2 06 FAQ
What does Sub-Zero code 20 2 06 mean?
Code 20 2 06 means the defrost bi-metal is mis-wired or improperly mounted, so the control saw abnormally high temperatures during defrost together with an inappropriate response from the bi-metal. Instead of reading a normal end-of-defrost signal, the board interprets the combination as a wiring or mounting fault and turns the SERVICE light on. The bi-metal that should sense and limit defrost heat is not connected or positioned to do its job.
How is 20 2 06 different from 20 2 05?
Both are mis-wired or misplaced defrost bi-metal faults, but 20 2 06 fires with the SERVICE light on because evaporator temperatures actually climbed too high during defrost, while 20 2 05 logs quietly with normal in-range temperatures and no SERVICE light. So 20 2 06 is the more serious version where the heat got away before the bi-metal could respond.
What does a technician check to confirm 20 2 06?
The technician removes the evaporator cover and meters the circuit to verify bi-metal wiring polarity, terminal routing, and clip placement. They confirm the leads are not swapped or on the wrong terminals, the connector is tight and not corroded, the harness is not chafed or pinched, and the clip is seated on the evaporator tubing so the switch reads true coil temperature.
Can I fix 20 2 06 myself?
Owner-safe steps are confirming the displayed code, noting whether frost is building up, checking whether the unit had recent service that may have disturbed wiring, and making sure the freezer is not overloaded so air can reach the evaporator. Correcting the wiring polarity and clip placement requires opening the evaporator and metering the circuit, which a technician should perform.
Is it safe to keep using the unit with 20 2 06?
This is a medium-urgency fault. The unit keeps cooling, but with the bi-metal not limiting defrost heat correctly you may see frost or ice on the evaporator and freezer walls, defrost cycles running too long, an unusually warm evaporator after defrost, and compartments drifting warmer over time. Schedule service before the defrost behavior worsens.
What gets repaired for 20 2 06 and what does it cost?
The fix is correcting the bi-metal wiring and remounting it against the evaporator; the defrost bi-metal (termination thermostat) is replaced if its sensing surface or clip is damaged, and the harness or connector is replaced if leads are chafed, corroded, or cannot hold a secure connection. We charge a flat $89 diagnostic, warranty the work 365 days, and you can call (650) 668-1554 to schedule.
What you'll typically see
- Service light is on and code 20 2 06 is displayed
- Frost or ice buildup on the evaporator or freezer walls
- Defrost cycles seem to run too long or terminate incorrectly
- Compartment temperatures drift warmer over time
- Evaporator area feels unusually warm after a defrost
Why 20 2 06 happens
The bi-metal leads may be swapped, loose, or routed to the wrong terminals after a prior repair. The bi-metal clip may have slipped off the evaporator tubing, so it no longer senses true coil temperature. A pinched or chafed harness near the evaporator can also confuse the reading the control receives.
Common causes
- Bi-metal wiring swapped or connected to the wrong terminals
- Bi-metal clip dislodged from the evaporator tubing
- Loose or corroded bi-metal connector
- Chafed or pinched harness between bi-metal and control board
- Damaged bi-metal that responds incorrectly to heat
Parts involved in 20 2 06
- Defrost bi-metal (termination thermostat) — If the sensing surface or clip is damaged and it cannot be remounted to read coil temperature correctly
- Bi-metal wiring harness or connector — If leads are chafed, corroded, or cannot hold a secure connection
What you can check yourself
- Confirm the displayed code and note whether frost is building up
- Verify the unit has not recently had service that may have disturbed wiring
- Make sure the freezer is not overloaded so air can reach the evaporator
- Record how often the code returns to share with the technician
When to book a pro
Verifying bi-metal wiring polarity, terminal routing, and clip placement requires removing the evaporator cover and metering the circuit, which a technician must perform to confirm correct mounting and prevent further defrost faults.
Have this code?